To Copy The System Settings From The First To The Second User Interface - Daikin Altherma 3 R F Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

9.1.3 To copy the system settings from the first to the second user interface

ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Installer settings
The system will restart.
OK
Confirm
Result: The system will restart.
If a second user interface is connected, the installer must first proceed below
instructions for the proper configuration of the 2 user interfaces.
1 Turn on the unit.
Result: When turned on for the first time, both user interfaces display:
U5:Auto address
Push 4 sec. to continue
2 Push
for 4 seconds on the user interface on which you want to proceed to
the quick wizard.
Result: This user interface is now the main user interface.
INFORMATION
While using the quick wizard on the main user interface, the second user interface
displays Busy and you cannot interact with it.
3 On the display, check if there is a data difference between both user
interfaces.
Result: For proper operation of the system, the local data on both user
interfaces must be the same. If they contain different data, both user
interfaces will display:
Synchronization
Data difference detected.
Please select action:
Send data
Confirm
4 To make the data equal on both user interfaces, select the required action:
▪ Send data: the user interface you are operating contains the correct data.
Copy this data to the other user interface.
▪ Receive data: the user interface you are operating does NOT contain the
correct data. Copy the data of the other user interface to this user interface.
5 Confirm to proceed.
Start copy
Are you sure you want to
start the copy operation?
OK
Confirm
Cancel
Adjust
Tue
15:10
Adjust
Cancel
Adjust
9
Configuration
|
Installer reference guide
111

Advertisement

Table of Contents
loading