5
|
Application guidelines
Underfloor heating or radiators – Multiple external room thermostats
Installer reference guide
30
A thermostatic valve is installed before the underfloor heating in each of the
other rooms.
INFORMATION
Mind situations where the main room can be heated by another heating source.
Example: Fireplaces.
Configuration
Setting
Unit temperature control:
#: [A.2.1.7]
Code: [C-07]
Benefits
Easy. Same installation as for one room, but with thermostatic valves.
Setup
A
Main leaving water temperature zone
B
Room 1
C
Room 2
a
External room thermostat
b
Bypass valve
For more information about connecting the electrical wiring to the unit, see:
-
"8.2 Connections to the outdoor
-
"8.3 Connections to the indoor
For each room, a shut-off valve (field supplied) is installed to avoid leaving water
supply when there is no heating or cooling demand.
A bypass valve must be installed to make water recirculation possible when all
shut-off valves are closed. To guarantee reliable operation, provide a minimum
water flow as described in table "To check the water volume and flow rate" in
"7.2 Preparing water
The user interface connected to the indoor unit decides the space operation
mode. Mind that the operation mode on each room thermostat must be set to
match the indoor unit.
The room thermostats are connected to the shut-off valves, but do NOT have to
be connected to the indoor unit. The indoor unit will supply leaving water all the
time, with the possibility to program a leaving water schedule.
2 (RT control): Unit operation is
decided based on the ambient
temperature of the user interface.
B
A
M1
a
4
unit" [
 90]
4
unit" [
 91]
4
piping" [
 65].
Value
C
b
M2
a
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F