Daikin Altherma 3 R F Installer's Reference Manual page 203

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
A.8
[D-01]
Contact type of preferential kWh rate PS installation?
A.8
[D-02]
Which type of DHW pump is installed?
A.8
[D-03]
Leaving water temperature compensation around 0°C.
A.8
[D-04]
Is a demand PCB connected?
A.8
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
A.8
[D-07]
Is a solar kit connected?
A.8
[D-08]
Is an external kWh meter used for power measurement?
A.8
[D-09]
Is an external kWh meter used for power measurement?
A.8
[D-0A]
--
A.8
[D-0B]
--
A.8
[D-0C]
--
A.8
[D-0D]
--
A.8
[D-0E]
--
A.8
[E-00]
Which type of unit is installed?
A.8
[E-01]
Which type of compressor is installed?
A.8
[E-02]
What is the indoor unit software type?
A.8
[E-03]
--
A.8
[E-04]
Is the power saving function available on the outdoor unit?
A.8
[E-05]
Can the system prepare domestic hot water?
A.8
[E-06]
Is a DHW tank installed in the system?
A.8
[E-07]
What kind of DHW tank is installed?
A.8
[E-08]
Power saving function for outdoor unit.
A.8
[E-09]
--
A.8
[E-0A]
--
A.8
[E-0B]
--
A.8
[E-0C]
--
A.8
[E-0D]
Is the system filled with glycol?
A.8
[E-0E]
--
A.8
[F-00]
Pump operation allowed outside range.
A.8
[F-01]
Above which outdoor temperature is cooling allowed?
A.8
[F-02]
--
A.8
[F-03]
--
A.8
[F-04]
--
A.8
[F-05]
--
A.8
[F-09]
Pump operation during flow abnormality.
A.8
[F-0A]
--
A.8
[F-0B]
Close shut-off valve during thermo OFF?
A.8
F-0C
Close shut-off valve during cooling?
A.8
[F-0D]
What is the pump operation mode?
(*1) EHFH03S18DJ3V + EKHVCONV3_
(*2) EHFH03S18DJ3V
Range, step
Default value
R/W
0: No
1: Active open
2: Active closed
3: Safety thermostat
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
R/W
0: No
1: Pwr consmp ctrl
R/W
0: Forced off
1: As normal
R/W
0: No
1: Yes
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0
2
0
0
0
R/O
0~5
0: LT split
R/O
0
R/W (*1)
0: Reversible (*1)
R/O (*2)
1: Heating only (*2)
R/O
2
R/O
0: No
1: Yes
R/O
0~1
1: Yes
R/O
0~1
1: Yes
R/O
0~6
1: Integrated
R/O
0~1
1: Enabled
1
0
0
0
R/W
0: No
1: Yes
0
R/W
0: Disabled
R/W
10~35°C, step: 1°C
20°C
3
5
0
0
R/W
0: Disabled
1: Enabled
0
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: Continuous
1: Sample
2: Request
7/7