Daikin Altherma 3 R F Installer's Reference Manual page 134

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

9
|
Configuration
Installer reference guide
134
#
Code
N/A
[F-0B]
INFORMATION
The setting [F‑0B] is only valid when there is a thermostat or external room
thermostat request setting (NOT in case of leaving water temperature setting).
Cooling: ONLY applicable when EKHVCONV3 is installed.
The shut-off valve closes, depending on [F-0C] when the unit is running in cooling
operation mode. Enable this setting to avoid cold leaving water through the heat
emitter and the forming of condensation (e.g. under floor heating loops or
radiators).
#
Code
N/A
[F-0C]
Operation range
Depending on the average outdoor temperature, the operation of the unit in space
heating is prohibited.
Space heating OFF temp: When the averaged outdoor temperature raises
above this value, space heating is turned OFF to avoid overheating.
#
Code
[A.3.3.1]
[4-02]
Automatic heating/cooling changeover
ONLY applicable when EKHVCONV3 is installed. The end-user sets the desired
operation mode on the user interface: Heating, Cooling or Automatic (see also
operation manual/user reference guide). When Automatic is selected, the
changing of the operation mode is based on:
Monthly allowance for heating and/or cooling: the end-user indicates on a
monthly base which operation is allowed ([7.5]: both heating/cooling or heating
ONLY or cooling ONLY). If the allowed operation mode changes to cooling ONLY,
the operation mode changes to cooling. If the allowed operation mode changes
to heating ONLY, the operation mode changes to heating.
Averaged outdoor temperature: the operation mode will be changed in order to
ALWAYS be within range determined by the space heating OFF temperature for
heating and the space cooling On temperature for cooling. If the outdoor
temperature drops, the operation mode switches to heating and vice versa. Note
that
the
outdoor
4
"9 Configuration" [
 108]).
Description
The shut-off valve:
0 (No)(default): is NOT influenced by heating or
cooling demand.
1 (Yes): closes when there is NO heating or
cooling demand.
Description
The shut-off valve:
0 (No): is NOT influenced by changing the space
operation mode to cooling.
1 (Yes)(default): closes when the space
operation mode is cooling.
Description
14°C~35°C
temperature
will
be
time-averaged
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
(see