To Access The Most Used Commands - Daikin Altherma 3 R F Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

9
|
Configuration

9.1.2 To access the most used commands

Installer reference guide
110
To access the installer settings
1 Set the user permission level to Installer.
2 Go to [A]:
> Installer settings.
To access the overview settings
1 Set the user permission level to Installer.
2 Go to [A.8]:
> Installer settings > Overview settings.
To modify an overview setting
Example: Modify [1‑01] from 15 to 20.
1 Go to [A.8]:
> Installer settings > Overview settings.
2 Go to the corresponding screen of the first part of the setting (in this example
[1-01]) by using the
INFORMATION
An additional 0-digit is added to the first part of the setting when you access the
codes in the overview settings.
Example: [1‑01]: "1" will result in "01".
Overview settings
01
00
00
01
15
04
05
08
09
0c
0d
Confirm
Adjust
3 Go to the corresponding second part of the setting (in this example [1-01]) by
using the
and
Overview settings
01
00
00
01
15
04
05
08
09
0c
0d
Confirm
Adjust
Result: The value to be modified is now highlighted.
4 Modify the value by using the
Overview settings
01
00
00
01
20
04
05
08
09
0c
0d
Confirm
Adjust
5 Repeat previous steps if you have to modify other settings.
6 Push
to confirm the modification of the parameter.
7 At installer settings menu, press
and
button.
02
00
03
00
06
07
0a
0b
0e
0f
Scroll
button.
02
00
03
00
06
07
0a
0b
0e
0f
Scroll
and
button.
02
00
03
00
06
07
0a
0b
0e
0f
Scroll
to confirm the settings.
ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10