1.SC Codes
SC752-55
Error Name
Perfect Binder: Main Grip Rotate Sensor Error
Pattern
D
Error Condition
The MG rotate HP sensor and MG rotate-to-binding position sensor went on at the same time.
Major Cause
MG rotate HP sensor defective
MG rotate-to-binding position sensor defective
Connector harness loose, damaged, or defective
Solution
Reconnect the connector.
Replace the MG rotate-to-binding position sensor.
Replace the slave control board.
Replace the sensor harness.
SC752-56
Error Name
Perfect Binder: Main Grip Open Sensor (R) Late Error
Pattern
D
Error Condition
At the start of the main grip open operation, the MG open sensor (R) did not go ON, even after the MG
motor (R) had operated for 3000 ms.
Major Cause
Main grip motor (R) defective
MG open sensor (R) defective
Solution
Reconnect the connector.
Replace the main grip motor (R).
Replace the MG open sensor (R).
436
Need help?
Do you have a question about the Pro 8300S and is the answer not in the manual?