2.
Harness is damaged, or there is grounding fault. Or it is not connected properly.
3.
TD sensor (SEN1) is defective.
4.
IOB is defective.
5.
BiCU is defective.
Solution
1.
Check the PCU drawer. Clean the drawer, and set it again.
2.
Reconnect the harnesses between the TD sensor and PCU drawer, between the PCU drawer and
IOB, and between the IOB and BiCU. Or replace the harnesses.
3.
Replace the TD Sensor (SEN1).
4.
Replace the IOB.
5.
Replace the BiCU.
SC687-00
Error Name
PER Not Received Error
Pattern
D
Error Condition
PER command cannot be received from the controller.
Major Cause
Communication error
Unexpected software error
Solution
Turn the main power OFF and then ON.
1.SC Codes