1.SC Codes
Re-set the value for glue level thermistor.
Replace the gluing unit.
Replace the master control board EEPROM
Replace the slave board.
Replace the master control board.

SC751-17

Error Name

Perfect Binder: Timing Sensor Adjustment High Value Error

Pattern
D
Error Condition
The timing sensor A/D input value was lower than 3.0 to 3.5V, and the A/D input value did not go higher
than 3.0 to 3.5V, even after the timing sensor D/A output value went higher than 3.5V.
Major Cause
Timing sensor connector loose, damaged, or defective
Sensor defective
Master control board disconnected, or defective
Solution
Reconnect the connector.
Clean the sensor.
Replace the timing sensor.
Replace the master control board
Replace the sensor harness.

SC751-18

Error Name

Perfect Binder: Cover Registration Sensor Adjustment High Value Error

Pattern
D
Error Condition
The cover registration sensor A/D input value was lower than 3.0 to 3.5V, and the A/D input value did
not go higher than 3.0 to 3.5V, even after the cover registration sensor output value output went higher
than 3.5V.