3
Commissioning as function module F24
Configuration example
The following example describes a specific configuration of a CPX terminal with digital and analog I/O
modules and MPA pneumatics, and the resulting allocation of I/O data, depending on the selected
mapping optimisation.
Configuration of the CPX terminal
Mo-
Electric modules
dule
no.
0
Bus node FB23-24 (F24)
with system diagnostics
1
Digital 8-fold input and 8-fold
output module
2
Analogue 4-fold input module
3
Digital 8-fold input module
4
Analogue 2-fold output module
5
Analogue 4-fold input module
6
MPA pneumatic module (type 32)
with electrical isolation
Sum of the respective address ranges
Module identifiers on the Festo Maintenance Tool (CPX-FMT) or handheld (CPX-MMI) for I/O mod-
1)
ules these are shown in the inspection window of the module.
Remote Ready bit always occupies the address space of 2 bytes in the bit range (RX, RY) at the end
2)
of the last station with 1 bit.
The system diagnostics (status bits and I/O diagnostic interface) occupies 16 I/Os (the first word)
3)
in the word range of the first station (RWr, RWw).
Tab. 3.2 Configuration example for the CPX terminal depicted in Fig. 3.3 andFig. 3.4
Festo – P.BE-CPX-FB23-24-EN – 1305a – English
Module
Assigned addresses
1)
identifier
RX
2)
FB24-RIO
2 bytes
8DI/8DO
1 byte
4AI
8DI
1 byte
2AO
4AI
MPA1S
4 bytes
RY
RWr
RWw
2)
3)
2 bytes
2 bytes
2 bytes
(1 word)
(1 word)
1 byte
8 bytes
(4 words)
4 bytes
(2 words)
8 bytes
(4 words)
1 bytes
4 bytes
18 bytes
6 bytes
(9 words)
(3 words)
3)