2
Installation as function module F24
Cable type
FANC - 110SBH 0.5 mm
2)
CSFV - 110SLAB
Kuramo Electric CO.LTD
1)
LEONI Protec Cable Systems GmbH, Art. No. L45467-Y19-C15
2)
Tab. 2.17 Field bus connection, cable type, terminating resistor
2.6
Pin assignment of power supply
Warning
• Only use PELV circuits in accordance with IEC/EN 60204-1 (protective extra-low
voltage, PELV) for the electrical power supply.
• Observe also the general requirements for PELV power circuits in accordance with
IEC/EN 60204-1.
• Only use voltage sources which ensure reliable electrical isolation of the operating
voltage in accordance with IEC/EN 60204-1.
Through the use of PELV circuits, protection against electric shock (protection against direct and indir-
ect contact) is ensured in accordance with IEC/EN 60204-1.
The current consumption of a CPX terminal depends on the number and type of integrated modules and
components.
In the CPX system description, read the information on power supply as well as on the
earthing measures to be carried out (P.BE-CPX-SYS-...).
32
2
1)
× 3
Terminating resistor
110 Ω, 0.5 W
110 Ω, 0.5 W
Festo – P.BE-CPX-FB23-24-EN – 1305a – English