Parameterisation

8.1

Address space (data length inputs/outputs)

The address space (data length inputs/outputs) provided by the module can be set using software.
The following variants for setting the address space (data length inputs/outputs) are possible:
Variant
Module code
(hex/dec)
2
0x200E/8206
2_OE
0x200F/8207
4
0x2010/8208
4_OE
0x2011/8209
8
0x2009/8201
3)
8_OE
0x200D/8205
16
0x2012/8210
16_OE
0x2013/8211
32
0x2014/8212
32_OE
0x2015/8213
1) PB = PROFIBUS; PN = PROFINET; EP = EtherNet / IP; EC = EtherCAT
2) The last 4 input bytes contain the IO-Link port qualifier information bytes for port 0 ... 3.
3) Factory setting
Tab. 10
The "IO-Link Device Tool" software can be used to set the address space (data length inputs/outputs)
è www.festo.com/sp.
The setting is saved permanently in the module. Changes only become effective after a restart of the
automation system CPX-AP.
8.2

IO-Link Device description file (IO-Link Device Description)

IO-Link Device information can be imported into the module via an IO-Link device description file.
The "Festo IO-Link Tool" software can be used to import the IO-Link device description file
è www.festo.com/sp.
9
Parameterisation
Various parameters are available for reading out information about the modules in an automation sys-
tem CPX-AP and adapting the modules to the application situation.
10
Supported
Module [byte]
network
1)
Inputs
PB, EP, EC
12
PN, EP
PB, EP, EC
20
PN, EP
PB, EP, EC
36
PN, EP
PB, EP, EC
68
PN, EP
PB, EP, EC
132
PN, EP
per port [byte]
Outputs
Inputs
2)
8
2
16
4
32
8
64
16
128
32
Festo — CPX-AP-I-4IOL-M12 — 2020-03
Outputs
2
4
8
16
32