gefran GFX4-IR Configuration And Programming Manual page 33

4-zone modular power controller for ir lamps and inductive loads
Table of Contents

Advertisement

Enable alarm
195
AL. n
57
Xb. f
Default:
SINGLE-PHASE LOAD: each A.HbX refers to its respective phase.
2-PHASE LOAD: single reference setpoint A.Hb1 and OR between phases 1, 2 and
phases 3, 4.
3-PHASE LOAD: single reference setpoint A.Hb1 and OR among phases 1, 2 and 3.
+ 8 HB reverse alarm
+ 16 relates to single setpoints and singled phases WITH 3-PHASE LOAD
56
XB. T
464
Alarm setpoints
55
A. x b1
502
A. x b2
503
A. x b3
NB: In case of 3-phase load, you can set a different value for parameter A.Hb1,
A.Hb2, A.Hb3 for each zone (ex.: to control an unbalanced 3-phase load).
737
xb. P
Calibration HB
112 bit
alarm setpoint for
zone
742
xb. t A
w
743
xb. P
758
Ir. 0 0
759
Ir. 0 1
760
Ir. 0 2
761
Ir. 0 3
767
Ir. 0 4
768
Ir. 0 5
769
Ir. 0 6
80415F_MSW_GFX4-IR_05-2019_ENG
R/W
Select number of enabled alarms
R/W
HB alarm functions
R/W
Delay time for activation of HB alarm
STATUS 11_W
R/W
HB alarm setpoint (scale points amme-
R/W
ter input - Phase 1)
HB alarm setpoint (scale points amme-
R/W
ter input - Phase 2)
HB alarm setpoint (scale points amme-
R/W
ter input - Phase 3)
Percentage HB alarm setpoint of
R/W
current read in HB calibration
OFF = Calibration not enabled
R/W
ON = Calibration enabled
R
CT read in HB calibration
R
Ou.P power in HB calibration
HB Calibration with IR lamp: current at
R/W
100% conduction
HB Calibration with IR lamp: current at
R/W
50% conduction
HB Calibration with IR lamp: current at
R/W
30% conduction
HB Calibration with IR lamp: current at
R/W
20% conduction
HB Calibration with IR lamp
(only for PA modality): current at 15%
R/W
conduction
HB Calibration with IR lamp
(only for PA modality): current at 10%
R/W
conduction
HB Calibration with IR lamp
(only for PA modality): current at 5%
R/W
conduction
See: Table of enable alarms
Table of HB alarm functions
0
Relay, logic output: alarm active at a load current value below
set point for control output ON time.
1
Relay, logic output: alarm active at a load current value above
set point for control output OFF time.
2
Alarm active if one of functions 0 and 1 is active
(OR logic between functions 0 and 1) (*)
3
Continuous heating alarm
7
Continuous cooling alarm
(*) minimum setpoint is set at 12% of ammeter full scale
The value must exceed the cycle time of the
0 ... 999 sec
output to which the HB alarm is associated.
Table settings STATUS 11_W (*)
bit
5
Feedback calibration
6
HB alarm calibration
With 3-phase load
With 3-phase load
0.0 ... 100.0%
3
0
30
0
(*) To safeguard the other bit, writing should
be done starting from the reading going to
change only the bit interested.
10.0
10.0
10.0
80.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
33