Softstart; Start Mode - gefran GFX4-IR Configuration And Programming Manual

4-zone modular power controller for ir lamps and inductive loads
Table of Contents

Advertisement

Read state
0
SELFTUNING STATE
bit
68
STATE OF DIGITAL
INPUT 1
bit
92
STATE OF DIGITAL
INPUT 2
bit
296

SOFTSTART

If enabled, this function partializes power based on a percentage of time elapsed since instrument switch-on compared
to the set time of 0.0 ... 500.0 min ("SoFt" parameter CFG phase). Softstart is an alternative to selftuning and is activated after
each instrument switch-on. Softstart is reset when switching to manual.
31
s. t v
147
SOF
30
RESTART
SOFTSTART
bit
Read state
63
STATE SOFTSTART
bit

START MODE

699
P. O NT
54
OFF = Selftuning in Stop
R
ON = Selftuning in Start
OFF = Digital input 1 off
R
ON = Digital input 1 on
OFF = Digital input 2 off
R
ON = Digital input 2 on
Autotuning and selftuning enable state
R
(FLG_PID)
Enable selftuning,
R/W
autotuning, softstart
R/W
Softstart time
OFF = -
R/W
ON = Restart Softstart
OFF = Softstart in Stop
R
ON = Softstart in Start
R/W
Start modes at Power-On
See: Table of digital input functions
bit
3
Selftuning on
6
Autotuning on
Selftuning, autotuning, softstart table
Autotuning
continuous
0
NO
1
YES
2
NO
3
YES
4
NO
5
YES
Autotuning One-shot
8*
WAIT
9
GO
10*
WAIT
11
GO
12*
WAIT
13
GO
(*) +16 with automatic switching in GO if PV-SP > 0.5% f.s.
+32 with automatic switching in GO if PV-SP > 1% f.s.
+64 with automatic switching in GO if PV-SP > 2% f.s.
+128 with automatic switching in GO if PV-SP > 4% f.s.
0.0 ...500.0 min
0*
Function at previous state
1
Software shutdown
2
Software startup
(*) digital input states always have priority
80415F_MSW_GFX4-IR_05-2019_ENG
Selftuning
Softstart