gefran GFX4-IR Configuration And Programming Manual page 52

4-zone modular power controller for ir lamps and inductive loads
Table of Contents

Advertisement

31
s. t v
140
diG.
618
diG. 2
29
AUTOTUNING
bit
Read state
28
AUTOTUNING STATE
bit
68
DIGITAL INPUT 1
bit
92
DIGITAL INPUT 2
bit
296
305
52
Enable selftuning,
R/W
autotuning, softstart
R/W
Digital input function
R/W
Digital input 2 function
OFF = Stop Autotuning
R/W
ON = Start Autotuning
OFF = Autotuning in Stop
R
ON = Autotuning in Start
OFF = Digital input 1 off
R
ON = Digital input 1 on
OFF = Digital input 2 off
R
ON = Digital input 2 on
Autotuning and selftuning
R
enable state (FLG_PID)
R/W
Instrument state (STATUS_W)
Selftuning, autotuning, softstart table
Autotuning
Selftuning
continuous
0
NO
1
YES
2
NO
3
YES
4
NO
5
YES
Autotuning One-shot
8*
WAIT
9
GO
10*
WAIT
11
GO
12*
WAIT
13
GO
(*) +16 with automatic switching in GO if PV-SP > 0.5% f.s.
+32 with automatic switching in GO if PV-SP > 1% f.s.
+64 with automatic switching in GO if PV-SP > 2% f.s.
+128 with automatic switching in GO if PV-SP > 4% f.s.
See: Table of digital input functions
See: Table of digital input functions
bit
3
Selftuning on
6
Autotuning on
Table of instrument settings
bit
0
-
1
Select SP1/SP2
2
Start/Stop Selftuning
3
Select ON/OFF
4
Select AUTO/MAN
5
Start/Stop Autotuning
6
Select LOC/REM
80415F_MSW_GFX4-IR_05-2019_ENG
Softstart
NO
NO
NO
NO
YES
NO
YES
NO
NO
YES
NO
YES
NO
NO
NO
NO
YES
NO
YES
NO
NO
YES
NO
YES
0
0
0
0