Tilt Lock Arm Assembly

Vari-Lite Part No: 10.9704.1751 (Rod)
Vari-Lite Part No: 10.9704.0753 (Lever, x2)
Vari-Lite Part No: 10.9704.1752 (Locking Pin)
To replace tilt lock assembly or its parts:
Step 1. Remove tilt lock side yoke arm cover following the procedure described in
Covers Removal" on page
Step 2. Using a 5/64" Allen Wrench, remove 1 of the levers (10.9704.0753) by loosening the cone
point set screw.
Note:
Drawing exploded and some
components removed for clarity.
Step 3. Loosen the cone point set screw in the locking pin.
Step 4. Slide the rod out of yoke arm and locking pin.
Step 5. Replace in reverse. Note there are holes in rod for set screws.
02.97 04.001 0 A
Note: All procedures are done with the power completely removed. Adhere to all warnings in this manual.
46.
Lever (x2)
Rod
Locking Pin