Zoom Belt - Philips VARI-LITE VL4000 Spot Service Manual

Spot luminaire
Hide thumbs Also See for VARI-LITE VL4000 Spot:
Table of Contents

Advertisement

Zoom Belt

Vari-Lite Part No: 54.9704.0135
To replace the zoom belt:
Step 1. Remove 1 x 6-32 x ¼" PPZ SEMS screw clamping belt to zoom lens.
Step 2. Remove 1 x 4-40 x 3/8" PFZ screw and remove stabilizer.
Pulley Cone
Set Screws
1/4" Hex Standoff
4-40 x 1/4" PPZ
SEMS Screw (x3)
Step 3. Loosen 1 x ¼" hex standoff and 3 x 4-40 x ¼" PPZ SEMS screws and remove belt.
Step 4. Replace in reverse.
02.97 04.001 0 A
Note: All procedures are done with the power completely removed. Adhere to all warnings in this manual.
S
P
: O
ERVICE
ROCEDURES
A
C
PTICS
SSEMBLY
OMPONENTS
Note:
Drawing exploded and some
components removed for clarity.
6-32 x 1/4" PPZ
SEMS Screw
Belt
4-40 x 3/8" PFZ Screw
Motor Stabilizer
Pulley
Zoom Belt
Note:
Drawing exploded and some
components removed for clarity.