Error Reset - Mitsubishi Electric MELSEC-L LD75P Reference Manual

Positioning module sample ladder
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

3.24 Error Reset

Function Overview
This program reads error codes and resets errors for Axis 1.
Program
This function uses the project (program name).
•LD-LD75_IEF_V100A_E(24RstErr)
Applicable Hardware and Software
It is the same as "Applicable Hardware and Software" of "3.1 Parameter Setting".
System Configuration
It is the same as "System Configuration" of "3.1 Parameter Setting"
This program uses the following devices.
No. Device
1
X3E
2
X1008
Conditions for Using Sample Ladder Programs
It is the same as "Conditions for Using Sample Ladder Programs" of "3.1 Parameter Setting"
Devices
This program uses the following devices.
No. Device
1
X3E
2
X1008
3
M28
4
M5370
5
M5380
6
D79
7
D96
Data Type
Application
Bit
Error reset command
Bit
Axis 1 Error detection signal
Data Type
Application
Bit
Error reset command
Bit
Axis 1 Error detection signal
Bit
Error reset
Bit
Error code acquisition complete device
Bit
Error reset complete device
Word
Error code
Word
Error reset request setting value
MELSEC-L LD75P/LD75D Positioning Module Sample Ladder Reference Manual
165/169
Remarks
-
-
Remarks
-
-
-
-
-
Obtains an error code.
Sets the error reset request
setting value.
LDM-M022-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents