2.14 Speed Change

Function Overview
This program performs the speed change for Axis 1.
Program
This function uses the project (program name).
•LD-LD75_NML_V100A_E(14ChgSpd)
Applicable Hardware and Software
It is the same as "Applicable Hardware and Software" of "2.1 Parameter Setting".
System Configuration
It is the same as "System Configuration" of "2.1 Parameter Setting"
This program uses the following devices.
No. Device
1
X0C
2
X32
Conditions for Using Sample Ladder Programs
It is the same as "Conditions for Using Sample Ladder Programs" of "2.1 Parameter Setting"
Devices
This program uses the following devices.
No. Device
1
X0C
2
X32
3
M11
4
M12
5
D11
6
D12
7
D13
Data Type
Application
Bit
Axis 1 BUSY signal
Bit
Speed change command
Data Type
Application
Bit
Axis 1 BUSY signal
Bit
Speed change command
Bit
Speed change command pulse
Bit
Speed change command storage
Word
Speed change value (low-order 16 bits)
Word
Speed change value (high-order 16 bits)
Word
Speed change request
MELSEC-L LD75P/LD75D Positioning Module Sample Ladder Reference Manual
50/169
Remarks
-
Performs the speed change.
Remarks
-
Performs the speed change.
-
-
Sets the speed change
value.
Sets the speed change
request.