Devices
This program uses the following devices.
No. Device
1
X0
2
X0C
3
X30
4
X31
5
M8
6
M9
7
M10
8
D8
9
D9
10
D10
Version Upgrade History
Version
Date
1.00A
2011/09/26
Data Type
Application
Bit
LD75 READY signal
Bit
Axis 1 BUSY signal
Bit
Manual pulse generator operation enable
command
Bit
Manual pulse generator operation disable
command
Bit
Manual pulse generator operation enable
command
Bit
Manual pulse generator operating flag
Bit
Manual pulse generator operation disable
command
Word
Manual pulse generator 1 pulse input
magnification (low-order 16 bits)
Word
Manual pulse generator 1 pulse input
magnification (high-order 16 bits)
Word
Manual pulse generator operation enable
Description
First edition
MELSEC-L LD75P/LD75D Positioning Module Sample Ladder Reference Manual
48/169
Remarks
-
-
Enables the manual pulse
generator operation.
Disables the manual pulse
generator operation.
-
-
-
Sets the manual pulse
generator 1 pulse input
magnification.
-
LDM-M022-A