Mitsubishi Electric MELSEC-L LD75P Reference Manual page 11

Positioning module sample ladder
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

Conditions for Using Sample Ladder Programs
Positioning Data Setting
The following explains the settings for the LD75 positioning module that the programs use.
(1) Setting for Positioning Data
a) Open the positioning data axis #1 setting screen and configure the setting as follows.
Project window [Intelligent Function Module] Module name [Positioning_Data_Axis_#1]
No.
Operation pattern
1
1:Continuous positioning control
2
1:Continuous positioning control
5
1:Continuous positioning control
10
1:Continuous positioning control
15
0:Positioning complete
Table 2-1-2 Positioning Data for Axis 1
Control system
02h:INC linear 1
01h:ABS Linear 1
04h:1-axis speed
control (forward run)
05h:1-axis speed
control (reverse run)
03h:1-axis
fixed-feed control
MELSEC-L LD75P/LD75D Positioning Module Sample Ladder Reference Manual
11/169
Acceleration
Deceleration
time No.
time No.
0:1000
0:1000
0:1000
0:1000
0:1000
0:1000
0:1000
0:1000
0:1000
0:1000
Positioning
Command
address
speed
200000 pulses
10000 pulses/s
100000 pulses
5000 pulses/s
20000 pulses/s
3000 pulses/s
250000 pulses
8000 pulses/s
LDM-M022-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d

Table of Contents