gefran SIEIDrive ADV50 Series Quick Start-Up page 64

V/f & sensorless vector ac drive
Table of Contents

Advertisement

Available languages

Available languages

Pr.
Explanation
Input Terminal for PID
10.01
Feedback
10.02
Proportional Gain (P)
10.03
Integral Time (I)
10.04
Derivative Control (D)
Upper Bound for
10.05
Integral Control
Primary Delay Filter
10.06
Time
10.07
PID Output Freq Limit 0 to 110%
PID Feedback Signal
10.08
Detection Time
Treatment of the
10.09
Erroneous PID
Feedback Signals
Gain Over the PID
10.10
Detection Value
Source of PID Set
10.11
point
10.12
PID Offset Level
Detection Time of PID
10.13
Offset
Sleep/Wake Up
10.14
Detection Time
10.15
Sleep Frequency
10.16
Wakeup Frequency
Minimum PID Output
10.17
Frequency Selection
Multi-function Output
11.00
Terminal MO2/RA2
Multi-function Output
11.01
Terminal MO3/RA3
Multi-function Output
11.02
Terminal MO4/RA4
Multi-function Output
11.03
Terminal MO5/RA5
Multi-function Output
11.04
Terminal MO6/RA6
11.05
Multi-function Output
Terminal MO7/RA7
24
ADV50 QS, SW-PW V1.11 / CTL V2.11
0: Positive PID feedback from external terminal
AVI (0 ~ +10VDC)
1: Negative PID feedback from external terminal
AVI (0 ~ +10VDC)
2: Positive PID feedback from external terminal
ACI (4 ~ 20mA)/ AVI2 (0 ~ +10VDC).
3: Negative PID feedback from external terminal
ACI (4 ~ 20mA)/ AVI2 (0 ~ +10VDC).
0.0 to 10.0
0.00 to 100.0 sec (0.00=disable)
0.00 to 1.00 sec
0 to 100%
0.0 to 2.5 sec
0.0 to 3600 sec (0.0 disable)
0: Warn and RAMP to stop
1: Warn and COAST to stop
2: Warn and keep operation
0.0 to 10.0
0.00 to 600.0Hz
1.0 to 50.0%
0.1 to 300.0 sec
0.0 to 6550 sec
0.00 to 600.0 Hz
0.00 to 600.0 Hz
0: By PID control
1: By minimum output frequency (Pr.01.05)
Group 11 Parameters for Extension Card
0: No function
1: AC drive operational
2: Master frequency attained
3: Zero speed
4: Over torque detection
5: Base-Block (B.B.) indication
6: Low-voltage indication
7: Operation mode indication
8: Fault indication
9: Desired frequency 1 attained
10: Terminal count value attained
11: Preliminary count value attained
12: Over Voltage Stall supervision
13: Over Current Stall supervision
14: Heat sink overheat warning
15: Over Voltage supervision
Settings
Italiano
Italiano
Factory
NOTE
Setting
0
1.0
1.00
0.00
100
0.0
100
60.0
0
1.0
0.00
10.0
5.0
0.0
0.00
0.00
0
0
0
0
0
0
0
English
English

Advertisement

Table of Contents
loading