Available languages

Control System
Frequency Setting Resolution
Output Frequency Resolution
Torque Characteristics
Overload Endurance
Skip Frequency
Accel/Decel Time
Stall Prevention Level
DC Braking
Regenerated Braking Torque
V/f Pattern
Frequency
Keypad
Setting
External Signal
Operation
Keypad
Setting
External Signal
Signal
Multi-function Input Signal
Multi-function Output Indication
Analog Output Signal
Alarm Output Contact
Operation Functions
Protection Functions
Display Keypad (optional)
Built-in Brake Chopper
Built-in EMI Filter
Enclosure Rating
Pollution Degree
Installation Location
Ambient Temperature
Storage/ Transportation
Temperature
Italiano
General Specifications
V/f or sensorless vector control with SPWM modulation (Sinusoidal Pulse
Width Modulation)
0.01Hz
0.01Hz
Including the auto-torque/auto-slip compensation; starting torque can be
150% at 3.0Hz
150% of rated current for 1 minute
Three zones, setting range 0.1-600Hz
0.1 to 600 seconds (2 Independent settings for Accel/Decel time)
Setting 20 to 250% of rated current
Operation frequency 0.1-600.0Hz, output 0-100% rated current
Start time 0-60 seconds, stop time 0-60 seconds
Approx. 20% (up to 125% possible with optional brake resistor or externally
mounted brake unit, 3-15hp (2.2-11kW) models have brake chopper built-in)
4-point adjustable V/f pattern
▲ ▼
Setting by
Potentiometer-5kΩ/0.5W, 0 to +10VDC, 4 to 20mA, RS-485 interface; Multi-
function Inputs 3 to 9 (15 steps, Jog, motopotentiometer)
Set by RUNand STOP
2 wires/3 wires ((MI1, MI2, MI3)), JOG operation, RS-485 serial interface
(MODBUS), programmable logic controller
Multi-step selection 0 to 15, Jog, accel/decel inhibit, 2 accel/decel switches,
counter, , external Base Block, ACI/AVI selections, driver reset, UP/DOWN
key settings, NPN/PNP input selection
AC drive operating, frequency attained, zero speed, Base Block, fault
indication, overheat alarm, emergency stop and status selections of input
terminals
Frequency / Current
Contact will be On when drive malfunctions (1 Form C/change-over contact
and 1 digital open collector output for standard type)
Built-in PLC, AVR, accel/decel S-Curve, over-voltage/over-current stall
prevention, 5 fault records, reverse inhibition, momentary power loss restart,
DC braking, auto torque/slip compensation, auto tuning, adjustable carrier
frequency, output frequency limits, parameter lock/reset, vector control, PID
control, external counter, MODBUS communication, abnormal reset,
abnormal re-start, power-saving, fan control, sleep/wake frequency, 1st/2nd
frequency source selections, 1st/2nd frequency source combination,
NPN/PNP selection, parameters for motor 0 to motor 3, DEB and OOB (Out
Of Balance Detection)(for washing machine)
Over voltage, over current, under voltage, external fault, overload, ground
fault, overheating, electronic thermal, IGBT short circuit, PTC
6-key, 7-segment LED with 4-digit, 5 status LEDs, master frequency, output
frequency, output current, custom units, parameter values for setup and lock,
faults, RUN, STOP, RESET, FWD/REV, PLC
ADV50-2015-XXX-2MF, ADV50-2022-XXX-2M-F/2T/4-F, ADV50-2022-XXX-
2MF/2T/4F, ADV50-2037-XXX-2T/4-FADV50-2037-XXX-2T/4F, ADV50-3055-
XXX-2T/4F, ADV50-3075-XXX-2T/4-F ADV50-3075-XXX-2T/4F, ADV50-3110-
XXX-4-F, ADV50-3110-XXX-4F
For 230V 1-phase and 400-460V 3-phase models.
IP20
2
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
o
o
o
-10
C to 50
C (40
C for side-by-side mounting) Non-Condensing and not
frozen
o
o
-20
C to 60
C
English
ADV50 QS, SW-PW V1.11 / CTL V2.11