gefran SIEIDrive ADV50 Series Quick Start-Up page 53

V/f & sensorless vector ac drive
Table of Contents

Advertisement

Available languages

Available languages

Pr.
Explanation
Mid-Point Frequency
01.40
(Fmid) (Motor 3)
Mid-Point Voltage
01.41
(Vmid) (Motor 3)
Minimum Output
01.42
Frequency (Fmin)
(Motor 3)
Minimum Output
01.43
Voltage (Vmin) (Motor
3)
Source of First
02.00
Master Frequency
Command
Source of First
02.01
Operation Command
02.02
Stop Method
PWM Carrier
02.03
Frequency Selections
Motor Direction
02.04
Control
02.05
Line Start Lockout
Loss of ACI Signal (4-
02.06
20mA)
Italiano
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
Group 2 Operation Method Parameters
0: Digital keypad UP/DOWN keys or Multi-
function Inputs UP/DOWN. Last used frequency
saved.
1: 0 to +10V from AVI
2: 4 to 20mA from ACI or 0 to +10V from AVI2
3: RS-485 (RJ-45)/USB communication
4: Digital keypad potentiometer
0: Digital keypad
1: External terminals. Keypad STOP/RESET
enabled.
2: External terminals. Keypad STOP/RESET
disabled.
3: RS-485 (RJ-45)/USB communication. Keypad
STOP/RESET enabled.
4: RS-485 (RJ-45)/USB communication. Keypad
STOP/RESET disabled.
0: STOP: ramp to stop; E.F.: coast to stop
1: STOP: coast to stop; E.F.: coast to stop
2: STOP: ramp to stop; E.F.: ramp to stop
3: STOP: coast to stop; E.F.: ramp to stop
1 to 15kHz
0: Enable forward/reverse operation
1: Disable reverse operation
2: Disabled forward operation
0: Disable. Operation status is not changed
even if operation command source Pr.02.01 is
changed.
1: Enable. Operation status is not changed even
if operation command source Pr.02.01 is
changed.
2: Disable. Operation status will change if
operation command source Pr.02.01 is
changed.
3: Enable. Operation status will change if
operation command source Pr.02.01 is
changed.
0: Decelerate to 0 Hz
1: Coast to stop and display "AErr"
2: Continue operation by last frequency
command
English
Settings
ADV50 QS, SW-PW V1.11 / CTL V2.11
Factory
NOTE
Setting
1.50
10.0
20.0
1.50
10.0
20.0
1
1
0
8
0
1
1
13