gefran SIEIDrive ADV50 Series Quick Start-Up page 60

V/f & sensorless vector ac drive
Table of Contents

Advertisement

Available languages

Available languages

Pr.
Explanation
Motor Rated Current
07.00
(Motor 0)
Motor No-Load
07.01
Current (Motor 0)
Torque
07.02
Compensation (Motor
0)
Slip Compensation
07.03
(Used without PG)
(Motor 0)
Motor Parameters
07.04
Auto Tuning
Motor Line-to-line
07.05
Resistance R1 (Motor
0)
Motor Rated Slip
07.06
(Motor 0)
Slip Compensation
07.07
Limit
Torque
07.08
Compensation Time
Constant
Slip Compensation
07.09
Time Constant
Accumulative Motor
07.10
Operation Time (Min.)
Accumulative Motor
07.11
Operation Time (Day)
Motor PTC Overheat
07.12
Protection
Input Debouncing
07.13
Time of the PTC
Protection
Motor PTC Overheat
07.14
Protection Level
Motor PTC Overheat
07.15
Warning Level
Motor PTC Overheat
07.16
Reset Delta Level
Treatment of the
07.17
Motor PTC Overheat
Motor Rated Current
07.18
(Motor 1)
Motor No-Load
07.19
Current (Motor 1)
20
ADV50 QS, SW-PW V1.11 / CTL V2.11
Settings
30: Control Board CPU WRITE failure (cF1.1)
31: Control Board CPU READ failure (cF2.1)
32: ACI signal error (AErr)
33: Reserved
34: Motor PTC overheat protection (PtC1)
35-39: Reserved
40: Communication time-out error of control
board and power board (CP10)
Group 7 Motor Parameters
30 %FLA to 120% FLA
0%FLA to 99% FLA
0.0 to 10.0
0.00 to 10.00
0: Disable
1: Auto tuning R1
2: Auto tuning R1 + no-load test
0~65535 mΩ
0.00 to 20.00 Hz
0 to 250%
0.01 ~10.00 Sec
0.05 ~10.00 sec
0 to 1439 Min.
0 to 65535 Day
0: Disable
1: Enable
0~9999(*2ms)
0.1~10.0V
0.1~10.0V
0.1~5.0V
0: Warn and RAMP to stop
1: Warn and COAST to stop
2: Warn and keep running
30 %FLA to 120% FLA
0%FLA to 99% FLA
Factory
Setting
FLA
0.4*FLA
0.0
0.00
0
0
3.00
200
0.10
0.20
0
0
0
100
2.4
1.2
0.6
0
FLA
0,4*FLA
Italiano
English
Italiano
English
NOTE

Advertisement

Table of Contents
loading

Table of Contents