Taylor C708 Operator's Manual page 35

Heat treatment soft serve freezers
Hide thumbs Also See for C708:
Table of Contents

Advertisement

(L/R) HPR>59F (15C)—The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) BRL>59F (15C)—The mix temperature in the
freezing cylinder (barrel) exceeded 59°F (15°C).
(L/R) TOO COLD—The mix temperature in the
freezing cylinder (barrel) has dropped below 10°F 
(-12°C).
Heat Cycle Summary
The HEAT CYCLE SUMMARY screen displays the hours
since the last Heat cycle, the hours since the product
temperature was above 150°F (65.6°C), and the number
of heat cycles completed since the last brush clean date.
HEAT CYCLE SUMMARY
H
R
S
S
N I
C
E
H
C
H
R
S
S
N I
C
E
1
5
0
H
C
S
N I
C
E
B
C
Heat Cycle Data
The HEAT CYCLE DATA screen contains a record of up
to 366 Heat Treatment Cycles. The most recent Heat
cycle data will be shown first.
Each Heat cycle record has three screens. The first
screen displays the month and day of the Heat cycle, the
start time and end time, and the fault description. The
bottom line displays the record number and indicates if a
power failure occurred during the Heat cycle (POWER
FAILURE IN HC).
HEAT TREAT CYCLE
01/01
02:00
NO FAULT FOUND
Press the Up Arrow key to advance forward through the
data pages. Press the Down Arrow key to reverse the
page direction.
Hopper and barrel temperature records for each side of
the freezer are displayed in the second and third screens.
The second screen shows the left side (L) side of the
freezer.
User Interface
The third screen shows the right side (R) of the freezer.
The top line of these screens shows the hopper (H) and
barrel (B) temperatures recorded at the end of the HEAT
TREAT CYCLE and indicates the side (L or R) of the
freezer.
The remaining lines indicate the following:
HEAT = Total time for the hopper (h) and barrel (b) to
reach 150.9°F (66.1°C).
OVER = Total time the hopper (h) and barrel (b)
temperature was above 150°F (65.6°C).
COOL = Total time the hopper (h) and barrel (b)
temperature was above 41°F (5°C) during the Cool
phase.
PEAK = Highest temperature reading for the hopper (h)
and barrel (b) during the Heat Treatment Cycle.
0
0
0
The HEAT time indicates the amount of time taken in
each zone to reach 150.9°F (66.1°C). Each zone must
remain above 150°F (65.6°C) for a minimum of 
35 minutes.
Press the Up Arrow key to advance to the next page or
the Down Arrow key to view the previous page. A Heat
05:14
Cycle Failure message will display on the first screen if a
failure occurred.
1
Models C708 & C716
USER INTERFACE
H: 40.9
B:26.3
HEAT
OVER
COOL
1:12
0:49
h
1:19
0:46
1:11
b
0:15
H: 38.0
B:23.7
HEAT
OVER
COOL
1:09
0:52
h
1:11
0:66
1:00
b
0:11
L
PEAK
161.0
169.7
5
R
PEAK
161.2
169.9
5-13