7.8 Set Alarm Response Actions

Alarm response actions will be activated when an alarm or exception occurs, including Event Hint
Display, Full Screen Monitoring, Audible Warning (buzzer), Notify Surveillance Center, Trigger
Alarm Output and Send Email.
Steps
1. Go to Menu → Configuration → Exceptions.
2. Check Enable Event Hint.
Note
When an event or exception happens, a hint can be displayed on the lower-left corner of live
view image. And you can click the hint icon to check the details. Besides, the event to be
displayed is configurable.
3. Set the type of event to be displayed on the image.
4. Choose the linkage action.
Full Screen Monitoring
When an alarm is triggered, the local monitor (VGA, HDMI or BNC monitor) display in full
screen the video image from the alarming channel configured for full screen monitoring.
If alarms are triggered simultaneously in several channels, their full-screen images will be
switched at an interval of 10 seconds (default dwell time). A different dwell time can be set
by going to Menu → Configuration → Live View.
Network Video Recorder User Manual
Figure 7-16 Event Hint Settings
86