AIR LOGIC POWER SYSTEMS (ALPS)

Supervisor Menu Introduction

The supervisor settings allow for turning on and off various functions and options.
Supervisor Menu
1
4
Option or Function
1. Options
2. System Bypass
3. Aux Test settings
4. Enable Auto Self-Test
5. ALPS
SPEEDGLIDER  ADVANCED OPERATOR MANUAL
2
5
Result or Function
Turns reject verification function on/off
Turns secondary Reject function on/off
Analog output for conveyor for customer conveyor speed following on/off
Turns manual mode on/off. Manual Mode ON will bypass the container
present photo eye and will make the test probes come down on every
stroke.
Turns Siren on/off
Turns System Bypass function on/off. In system bypass containers will pass
through the SpeedGlider untested
These functions turn on various auxiliary outputs based on certain functions
(Not shown above) This option if selected allows the SpeedGlider to perform
manual self-test every certain number of containers possessed. The stop &
Alarm selection means the SpeedGlider will stop if the container is not reject
after an auto self-test is done.
ALPS Technicians only
46
3
TM 2012-005 REV00 © 10/25/2012
THE SUPERVISOR MENU