It is assumed that frame relay service is turned on at the site.
1. Select the Easy Install feature.
Main Menu
2. Enter the Node IP Address and Subnet Mask.
3. Set TS Access to DLCI, then select a DLCI on the network interface that
will be used for the troubleshooting access link.
4. Create a Dedicated Network Management Link, selecting a DLCI for the
management link at the Which DLCI would you like to Create a
Dedicated Network Management Link on? prompt, which will be used
by the NOC to access the unit.
5. For a FrameSaver SLV 9128-II that will use its Ethernet port, select the Ethernet
Port Options Screen and configure the following:
– Enable Interface Status. If the NMS will be on a different subnet than the unit,
enter Yes at the Would you like to set the Node's Default IP
Destination to Ethernet? prompt. Otherwise, enter No.
– If the IP Address and Subnet Mask are unique to the interface, enter them for
the port; otherwise, the Node IP Address and Subnet Mask will be used.
– Enter the Default Gateway Address; the IP Address that will be used for packets
without a route.
– Enable Proxy ARP if the unit will proxy for downstream FrameSaver units
learned via the proprietary RIP (Routing Information Protocol) feature.
– Press the Esc key to return to the Easy Install screen.
6. Configure the T1 network interface options to match the service provider's settings.
7. Save the configurations.
8. Install the network cable (see Connecting to the Network on page 17). The
FrameSaver unit starts discovering DLCIs and network time slots (see Automatic
Configuration on page 12).