Paradyne FrameSaver SLV 9128 Installation Instructions Manual page 20

1-slot unit
Hide thumbs Also See for FrameSaver SLV 9128:
Table of Contents

Advertisement

Connecting to a DTE (Router or FRAD)
1. Connect one end of the DTE's V.35 cable to the data port.
2. Plug the other end of the cable into the DTE.
3. Tighten the screws on each side of the connector to secure the cable.
P
O
R
T
1
POWER
DTE
4. Repeat Steps 1– 4 of this procedure for Port-2.
5. Verify that the Port OK LED is on. If not, make sure both ends of the cable are
properly seated and secured. Then, check the DTE; RTS or DTR could be down
on the DTE.
– The FrameSaver SLV 9128 has a Port OK LED for each port.
– The FrameSaver SLV 9128-II has one Port OK LED for both ports. If either port
is enabled and active, the LED is on. If both ports are enabled and one of the
ports is inactive, the LED is off.
6. Check Health and Status messages in the left column of the System and Test
Status screen for messages.
Main Menu
– If System Operational appears, the port interface is set up correctly and
is operational.
– If not, refer to Status Information in the User's Guide.
NOTE:
When any error conditions are detected, a status message appears along the
bottom right corner of the screen.
P
O
R
T
2
COM
DSX
Status
System and Test Status
MODEM
DBM
NET
ENET
00-16845