3.4
Network interfaces
3.4.1
E1 (2-Mbit/s) interface (Module Slot 1 and/or 2)
With the ETI module, the system provides an ETI input/output. In addition, either a
second ETI module or the Dual LAN module can be equipped.
The following options are possible: Monitoring Output if two ETI modules are
installed or EDI/ETI converting if the EDI upgrade is available.
Pin assignment: CLOCK, BNC SOCKET "1/2 CLOCK"
Pin
Signal
1
1
Data – T3 in/ T3 out
2
GND
2
Pin assignment: E1 IN
Pin
Signal
1
1
Data – F1 in
2
GND
2
Pin assignment: E1 OUT
Pin
Signal
1
1
Data – F1 out
2
GND
2
Electrical characteristics
Amplitude: 0,5 to 3,5 V
0P
Impedance: 75 Ohm unbalanced
Range:
100 m
Electrical characteristics
Amplitude: 3 V
PP
Impedance: 75 Ohm unbalanced
Range:
100 m
Electrical characteristics
Amplitude: 3 V
PP
Impedance: 75 Ohm unbalanced
Range:
100 m
(Input)
17