Front Reels Stop Under Load
Cause
_________________________________________________________________________________________
R1 bypassing.
_____________ ________________ ______ ________________ ______ ________________ __________________________________
__
__
Internal leakage (by-passing oil) in reel motor.
_____________ ________________ ______ ________________ ______ ________________ __________________________________
__
__
P1 pump section inefficient.
Front Reel Speed Erratic
Cause
_________________________________________________________________________________________
Reel bearing or bedknife to reel adjustment too tight.
_____________ ________________ ______ ________________ ______ ________________ __________________________________
__
__
Electrical problem.
REAR Cutting Unit Problems
Cause
_________________________________________________________________________________________
For problems with rear cutting unit reel operation, re-
fer to the Correction recommended for the front cut-
ting units.
NOTE: Rear cutting unit lift functions are control
led by P1 (front cutting unit) circuits of control valve.
®
Reelmaster
5100-D
__
__
__
__
__
__
__
__
__
Page 4 - 21
Correction
Check relief pressure at port G1 of valve block and
adjust valve if necessary.
Do cartridge valve service procedure for valve R1.
Replace R1 with a new valve.
__
Excessive case drain flow may identify faulty motor.
Use hydraulic tester to perform reel motor efficiency
test. Repair or replace reel motor if faulty.
__
Repair or replace pump.
Correction
See Chapter 8 - Cutting Units.
__
See Chapter 5 - Electrical System.
Correction
Substitute
R1 with R2
S1 with S2
S8 with S9
VS1 with VS2
__
___
______________________________
___
______________________________
__
___
______________________________
__
Troubleshooting