Transmission Operating Hot - Toro Reelmaster 5100-D Service Manual

Hide thumbs Also See for Reelmaster 5100-D:
Table of Contents

Advertisement

Machine Travels Too Far Before Stopping When Traction Pedal is Released
Cause
__________________________________________________________________________________________
Traction linkage out of adjustment.

Transmission Operating Hot

Cause
__________________________________________________________________________________________
Engine RPM too low.
________________________________________________________________________________________________________________________ ________________________________
Transmission reservoir oil level too low.
________________________________________________________________________________________________________________________ ________________________________
Cooling system not operating properly.
________________________________________________________________________________________________________________________ ________________________________
Faulty oil cooler bypass relief valve.
________________________________________________________________________________________________________________________ ________________________________
Charge pressure too low.
________________________________________________________________________________________________________________________ ________________________________
Traction pressure too high.
________________________________________________________________________________________________________________________ ________________________________
Traction pressure too low.
Troubleshooting
Correction
Adjust traction linkage.
Correction
Adjust, use tachometer.
Fill to proper level.
Clean screen, oil cooler and radiator. Repair fan or
belt. Check coolant level and add coolant as neces­
sary.
Check for restricted oil cooler and repair or replace
as necessary.
Inspect and clean or replace oil cooler bypass relief
valve.
Inspect for plugged transmission filter and replace if
necessary.
Inspect charge relief valve and clean or replace if
faulty.
Inspect charge pump and repair or replace if faulty.
Reduce transmission load.
If pressure is low in only one direction (forward or
reverse) check affected system relief valve and
repair or replace if faulty.
Repair or replace transmission (pump & motor).
Page 4 - 16
®
Reelmaster
5100-D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents