Front Reels Turn Too Fast; Front Reels Turn In Only One Direction - Toro Reelmaster 5100-D Service Manual

Hide thumbs Also See for Reelmaster 5100-D:
Table of Contents

Advertisement

Front Reels Turn Too Fast

Cause
__
________________________________________________________________________________________
VS1 not operating properly.

Front Reels Turn in Only One Direction

Cause
__
________________________________________________________________________________________
S8 not shifting.
Front Reels Stop or Won't Start – During Backlap Only
Cause
__
________________________________________________________________________________________
Motors bypassing.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
Load too high for motor.
Troubleshooting
__
__
__
Page 4 - 20
Correction
Do electrical diagnostics to make sure that voltage
is being applied to VS1 and that there is no electri ­
cal fault. See Chapter 5 - Electrical System.
Do cartridge service procedure for VS1.
Interchange VS1 with VS2 and check operation. Re­
place VS1 if faulty.
Correction
Do electrical diagnostics to make sure that voltage
is being applied to S8 and that there is no electrical
fault. See Chapter 5 - Electrical System.
Do cartridge valve service procedure for valve S8.
Interchange S8 with S9 and check operation. Re­
place S8 if faulty.
Correction
Increase flow to motors by adjusting HOC selector
knob.
__
__
Decrease load
__
®