Type of fitting
Important user information
The glass ceramic hob is intended to be fitted
in a kitchen worktop or the like. If you have
the requisite skills, you can fit the hob your-
self. However, the electrical connection must
be carried out by authorised specialist staff.
Requirements
To ensure proper operation, the following re-
quirements must be met:
– The hob complies with heat protection
class 'Y' (EC 335-2-6), which means that
with higher kitchen furnishings or walls it
may be installed on only one side. The
built-in furniture must have coverings and
the adhesives used must be heat-resistant
(100 °C). If this is not the case, this can
lead to deformation or detachment of the
covering surface. If you do not know the
thermal resistance of your kitchen furni-
ture, leave a gap of approximately 2 cm
between the furniture and the stove.
– The distance between the hob and the ex-
tractor hood must be at least 760 mm.
– Always install exhaust hoods in accord-
ance with their user manuals.
– Do not place the cooker directly next to a
refrigerator or freezer. This will increase its
energy consumption unnecessarily due to
heat dissipation.
– Below the complete recess you must leave
at least 50 mm of free space for ventilation
purposes. In this area, there must not be
any heat-sensitive objects (cabinet bases,
drawers etc.). Any side walls or drawers
which are present must be sawn out or
dismantled accordingly.
Type of fitting
Preparing food
To ensure proper operation, the following re-
quirements must be met:
– The worktop must be at least 30 mm thick
and at least 590 mm deep, oriented hori-
zontally and sealed against overflowing
liquids on the wall side.
– The hob must be surrounded by at least
50 mm of worktop on all sides.
min. 760 mm
min. 50 mm
min. 20 mm
If the hob is separated from the rest of the
mounting cupboard using a horizontal fixing
plate, the space between the base of the ap-
pliance and the fixing plate must be at least
50 mm high.
– If the hob is separated from the rest of
the mounting cupboard by a vertical fixing
plate, the space between the wall and the
fixing plate must be at least 20 mm.
– At the back of the fixing plate, a square
opening with a side diameter of at least
80 mm must be cut out.
Page GB-19
Luftauslass
min. 5 mm