Festo MS6-SV Operating Instructions Manual page 46

Soft start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6−SV
Example for fault code 6
1
Fig. 17
After four short flash pulses on the Power LED (1), there are six long flash pulses
on the Fault LED (2). This indicates fault code 6, a pneumatic fault. A pneumatic
fault occurs if, for example, the operating pressure is below the minimum pressure
or if there is no pressure at all.
Eliminating the fault when this fault code appears:
Check the compressed air supply
Check the voltage supply
Check the installation of the signal lines
Put the device into operation (è Chapter 7, Startup")
Replace the device if the fault occurs again
46
2
Festo MS6−SV 0706NH English
1

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents