M&D Procedures
Below is a listing of Maintenance & Diagnostic (M&D) Procedures and their function:
NOTE: For a complete list of M&D procedures including, their scope, time to
RSH
1119 Transport Calibration
3222 RSH Bar Code Calibration
3252 RSH Bar Code Reader Test
3317 RSH Test
3323 RSH Section test
3610 Sample Handler LLS
5501 RSH Motor Test
5506 RSH Sensor Test
5507 RSH Indicator Lights Test
6008 Controller Configuration
6311 RSH Cleaning
1-10
FOR INTERNAL USE ONLY
complete, user, status, and special tools, refer to the ARCHITECT RSH Service
and Support Manual, Procedures Section.
• Aligns the Carrier Transport to the bays and Carrier Positioner.
• In addition, the Carrier Positioner back lash and pitch are calculated.
• Calibration positions for Sample ID bar codes are defined for the RSH bar
code reader.
• Moves a carrier from a bay and section to the bar code reader where the
carrier and sample tubes are read.
• Test sample carrier movements from the RSH bay 1, bar code reader,
aspiration point(s). All other carriers move from the RSH bays to the carrier
positioner(s) and back to the original bay.
• Tests the ability of the RSH carrier transport to pick up a carrier from a
specific location and return it to that location.
• Subset of M&D 3317 RSH Test.
• Tests the sample pipettor ability to detect liquid at sample aspiration point
• LLS data analyzed: noise while in air, difference between the average LLS
read in air and the average LLS read in liquid, and maximum LLS read in air.
This M&D is found under Module 1 instead of RSH.
• Used to home the following RSH motors: carrier transport X, carrier
transport theta, carrier transport Z, and carrier positioner.
• Tests the carrier transport and carrier positioner sensors.
• Use this procedure to test the RSH indicator lights.
• Used to configure the PM and RSH controller board after replacement.
Bootcode is downloaded to the RSH or Process Module CPU. This
procedure configures the module so new boot code will be downloaded into
memory during the next power cycle.
A power cycle must be performed for changes to take effect.
• Provides instructions for cleaning the following RSH components:
- Tray bays
- Priority sections
- Carrier transport arm and guard
- RSH covers
- Carrier positioner