Figure 3-2: GPS Antenna
3.3 Connect Cables
3.3.1 Cabling Guidelines
The Nova-233 eNB has several interfaces on the bottom and side of the unit. Refer to previous
Figure 2-1 and Table 2-3. Please review the following guidelines concerning cable layout and
installation. Follow all specifications provided by manufacturers of non-Baicells products used.
General guidelines:
RF antenna feeder cable bending radius: 7/8" > 250 mm, 4/5" > 380 mm or as specified
•
by the manufacturer
•
Jumper cable bending radius: ¼" > 35 mm, ½" (super soft) > 50 mm, ½" (normal) > 127
mm or as specified by the manufacturer
•
Power cable and grounding cable bending radius: > triple the diameter of the cable or
as specified by the manufacturer
Optical fiber bending radius: 20 times the diameter of the optical fiber or as specified
•
by the manufacturer
•
Recommend not binding together the cables
Attach a label to identify each cable
•
Optical fiber cable layout guidelines:
Do not coil or twist the cable
•
•
Do not bind on the turn in the cable
•
Do not pull or weigh down the optical fiber
Grounding layout guidelines:
The grounding cable must connect to the grounding point
•
The grounding cable must be kept separate from the signal cables, with enough
•
distance to avoid interference with communications signals
14