6. Configure the eNB's local gateway (LGW) connection to the backhaul network. The eNB splits
the data plane and control plane. The data plane is sent out the LGW path, while the control
plane is routed through the IPSec tunnel to the CloudCore EPC.
a. Go to the Network > LGW menu (Figure 3-13). LGW should be enabled.
b. Select one of 3 LGW modes:
i. NAT - Network Address Translation modifies the network address in the IP
ii. Router - Enable static IP addressing, and identify the range of addresses. The
iii. Bridge - Layer 2 will create a virtual interface for each CPE that attaches
Figure 3-13: LGW
packet headers. To reach a CPE remotely, enter:
https://<eNB IP address><5+last 4 digits of CPE IMSI>
Leave the CPE Web GUI https port as 433; do not change the port number. IP
binding uses address range 10.10.0.1 to 10.10.0.254.
LGW will assign a local IP address when a CPE attaches. IP binding uses
address range 10.10.0.1 to 10.10.0.254.
using a DHCP request to create a 1:1 mapping between the CPE IP address
(from the EPC) and the LGW IP addresss. A CPE's MAC address is generated
from its IMSI: Convert the last 12 digits to hex, and then prefix it with "8A".
For example, if the IMSI = 311980000002918, the MAC would be
8A:E4:2C:8D:53:66.