Msi Set Length 1 - Datalogic PowerScan 9100 Series Product Reference Manual

Linear imager bar code reader
Table of Contents

Advertisement

Enter/Exit Programming Mode

MSI Set Length 1

This feature specifies one of the bar code lengths for
Length 1 is the minimum label length if in
fixed length if in
characters only. The length can be set from 01 to 50 characters.
Table 26
detailed instructions on setting this feature.
Table 26. MSI Length 1 Setting Examples
STEP
ACTION
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT MSI LENGTH 1 SETTING
Scan Two Characters From
4
Appendix D, Keypad
5
Scan ENTER/EXIT PROGRAMMING MODE
Select MSI Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
202
Fixed Length
provides some examples for setting Length 1. See
EXAMPLES
01 Characters
'0' and '1'
01 = Length 1 is 1 Character
DEFAULT
Variable Length
Mode. Length includes the bar code's data
07 Characters
15 Characters
'0' and '7'
'1' and '5'
To configure this feature, scan the ENTER/
EXIT bar code above, then the bar code at
left followed by digits from the Alphanu-
meric characters in
Appendix D, Keypad
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
CANCEL
PowerScan™ PD9130/PBT9100/PM9100
MSI Length
Control.
Mode, or the first
page 297
for
50 Characters
'5' AND '0'

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerscan pd9130Powerscan pbt9100Powerscan pm9100