Xenus
power, regen, & brake connectIons
DANGER: HIGH VOLTAGE
CIRCUITS ON J1, J2, J3, J4
ARE CONNECTED TO
MAINS POWER
BRAKE
BRAKE
+
+24 Vdc
0.5 Adc
-
24V Power Supply
Required for
Drive Operation
notes:
1) Items marked with CE are required for standards conformance.
2) In the end product installation, a ul RC (Recognized Component) SPD (Surge Protective Device) type 1CA, 2CA, 3CA
or a ul listed (VZCA) SPD type 1, 2, or 3 rated 2500 V, with a minimum SCCR of 5 kA, 240 Vac, and surge voltage
monitoring needs to be provided if the over-voltage category of the installation is greater than Category ii.
When this occurs, the purpose of the SPD is to establish an over-voltage CAT ii environment for the drives.
3) The line filter used in CE conformance testing was a Filter Concepts 3F15.
4) Fuses and/or circuit breakers are optional and can be selected by the user to meet local codes and/or
machine construction requirements.
5) The internal regen resistor of the xP2 must be unplugged when using an external regen resistor.
only one regen resistor can be connected to the Regen connector J2.
Copley Controls, 20 Dan Road, Canton, MA 02021, USA
Tech Support: E-mail: sales@copleycontrols.com, Web: http://www.copleycontrols.com
PLUS
Xenus Plus 2-Axis
A
B
BRAKE
5
+24V
4
+24V
3
A BRK
2
B BRL
1
24V RTN
Frame Grounding Tab
2-Axis CANopen
POWER
L3
5
4
J1
3
L2
2
L1
1
REGEN
H
1
J2
L
2
J5
3
Frame Ground
keep the chassis grounding
connections short for best
shielding performance
Tel: 781-828-8090
XP2
Rev 01
SPD = Surge Protection Device
SPD
*
Fuse
*
Fuse
*
Fuse
Earth
100~240 Vac
47~63 Hz
*
Fuse
*
Fuse
External Regen
*Optional
Resistor
Fax: 781-828-6547
Page 31 of 34
RoHS
3Ø
L3
1Ø
N
L2
H
L1
AC MAINS:
1Ø or 3Ø
Need help?
Do you have a question about the Xenus Plus XP2 Series and is the answer not in the manual?
Questions and answers