X2 Profinet - Siemens SINUMERIK 828D PPU Series Manual

Hide thumbs Also See for SINUMERIK 828D PPU Series:
Table of Contents

Advertisement

7.7.3.2

X2 PROFINET

Requirement
The I/O module has certified PROFINET interfaces, however their functionality cannot be fully
utilized within the scope of the SINUMERIK 828D control system. Networking within
SINUMERIK 828D is performed via a PLC I/O interface, which is based on PROFINET.
Data Transmission Rate and Cables
The interfaces are designed for full-duplex mode; in other words, the ports can both transmit
and receive. When connecting I/O modules to the SINUMERIK 828D, please use the
preassembled SINAMICS DRIVE-CLiQ signal cables; from a technical point of view, these are
also suitable for use with PROFINET:
● Article number: 6FX2002-1DC00-...
● The transmission characteristics of these cables meet the requirements of CAT5.
● Data transmission speed: 100 Mbps (fast Ethernet).
● The maximum length of the connections between the end device and network component
Pin assignment
Table 7-85
Pin
1
2
3
4
5
6
7
8
LED displays
For diagnostic purposes, the RJ45 sockets are each equipped with a green and a yellow LED.
This allows the following information on the respective PROFINET port to be displayed:
Table 7-86
Name
Link
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
or between two network components (e.g. switch ports) must not exceed 70 m.
Pin assignment - PROFINET X2, Port 1 and Port 2
Signal name
Signal type
TX+
O
TX-
O
RX+
I
N.C.
-
N.C.
-
RX-
I
N.C.
-
N.C.
-
PROFINET ports LED displays
Color
Green
Meaning
Transmit data +
Transmit data -
Receive data +
Not assigned
Not assigned
Receive data -
Not assigned
Not assigned
Status
Meaning
Lit
100 Mbit link available
Off
Missing or faulty link
Connectable components
7.7 PP 72/48D 2/2A PN
193

Advertisement

Table of Contents
loading

Table of Contents