Maintenance and Repair

10 Maintenance and Repair

10.1 Maintenance tasks

The servomotors are largely maintenance free. Only the
bearings and the shaft seals are subject to wear.
The maintenance tasks listed in the following table may be
performed by the customer. No other tasks are required.
Send the servomotor to Danfoss if it needs to be (fully)
overhauled.
Component Maintenance
Maintenance
Task
Interval
Servomotor Clean
Regularly or
as necessary
Bearings
Check for
As part of
bearing noise
regular
operational
inspection
Shaft seal
Replace shaft
Every 2 years Always replace
seal
Hybrid
Check for
Every 6
cable
damage and
months
wear
Brake
Danfoss
Number of
(option)
Service
allowed
emergency
stops
exceeded
Table 10.1 Overview of Maintenance Tasks

10.1.1 Replacing the Shaft Seal

NOTE
Use only manufacturer spare parts. Danfoss accepts no
responsibility for any damage resulting from the use of
parts not approved by Danfoss.
The spare parts kit (shaft seal, grease and service
instructions) can be ordered under part number 175G7706.
A special tool is necessary for fitting the seal. It can be
ordered under part number 175G7707 with the first order.
®
VLT
ISD 410 Servomotor Operating Instructions

10.2 Inspection during Operation

Carry out regular inspections during operation. Check the
servomotors at regular intervals for anything unusual.
Pay particular attention to:
Instruction
Clean the surface
with a dry cloth
Order a new ISD
servomotor when
the forward motion
In the event of irregularities or problems, see 9.1 Trouble-
limit is reached
shooting.

10.3 Repair

If damaged or worn:
replace hybrid cable
NOTE
(see
Always return defective servomotors to Danfoss
chapter10.3.1 Cable
Replacement)
The repair tasks listed below may be performed by the
Inform Danfoss
customer.
HIGH VOLTAGE
Potentially lethal voltage is present on the connectors.
Before working on the power connectors (disconnecting or
connecting the cable), disconnect the power supply
module from the mains and wait for the discharge time to
elapse.
®
MG75D102 - VLT
is a registered Danfoss trademark
Unusual noises
Overheated surfaces (temperatures up to 100 °C
may occur in normal operation)
Uneven running
Strong vibrations
Loose fastenings
Condition of electrical wiring and cables
Poor heat dispersion
WARNING
10
10
33