Selection of Voltage/Current at analog inputs / output and Pressure sensor
In addition to programming the parameter (PAR 1602 - 1652 - 1898) the position of switches P3-P4-P5 on the I/O card
must also be checked.
Jumper (I/O card)
P2
AIS : Pressure sensor input
P3
AI1: Analog input
P4
AI2: Analog input
P5
AI2: Analog output
Analog output (AO)
ADP200 • Quick installation guide - Specifications and connection
Description
Type
Input current
Input R
Resolution
Precision
Isolation
-
+
P2 P3 P4
P5
ON
OFF
ON = I
OFF = V
ON = I
OFF = V
ON = I
OFF = V
See figure
Description
Type
Output voltage
Load
Resolution
Precision
Isolation
Description
Type
Output current
R load
Resolution
Precision
Features
Current differential
0 (4) mA to 20 mA
500 Ω
12 Bits (11 + sign)
1% of full scale
NO
AI-X
OP
500
AI-X
(*)
(*) Select input V/I (V=OFF, I=ON)
I
Parameter combination
1502
1602
Analog inp 1X type
1652
Analog inp 2X type
1898
Analog out 2X type
Features
Single-ended in voltage
0 to 10V
5 mA @ ± 10 V - R
12 Bits
1% of full scale
NO
Features
Single-ended in current (only output 2)
0 (4) mA to 20 mA
500 Ω
12 Bits
1% of full scale
AI-X
V
Analog inp 1 type
= 2.2 kΩ
l