gefran ADP200 Quick Start Up Manual, Specification And Installation page 70

Vector inverter for hybrid injection molding machines
Hide thumbs Also See for ADP200:
Table of Contents

Advertisement

Step 4 - Setting encoder parameters (Standard card EXP-RES-I1-ADP)
The incorrect configuration of the encoder tension can permanently damage the device; therefore, it is advisable to
check the values on the encoder's specification plate.
Caution
03 STARTUP WIZARD
Set encoder param?
E=Yes
Proceed to the next step.
Step 5 - Encoder phasing (Standard card EXP-RES-I1-ADP)
ADP200 drives have a command to start automatic phasing of the resolver.
Phasing must be repeated whenever:
-
the drive is replaced (alternatively, download parameters taken from previous drive)
-
the motor is replaced
-
the encoder is replaced
Note !
For more information see parameters 17.23 PAR 2190 Autophase rotation and 17.24 PAR 2192 Autophase still on "Functions description and parameters
list" manual (ADP200 Vector inverter for Hybrid injection molding machines).
See section A.3.2 Phasing in the Appendix for further information.
Step 5A - Encoder phasing with rotating motor
03 STARTUP WIZARD
Run phasing rot?
E=Yes
Auto phase
Progress 10%
Press ESC to abort
Step 5B - Encoder phasing with still motor
03 STARTUP WIZARD
Run phasing still?
E=Yes
Auto phase
Progress 10%
Press ESC to abort
70
E
x 4
Down=Next
03 STARTUP WIZARD
E
Close Enable in p ut
Down=Next
Esc=Abort
(1)
(2)
Auto phase
Progress 100%
(5)
03 STARTUP WIZARD
E
Close Enable still
Down=Next
Esc=Abort
(1)
(2)
Auto phase
Progress 100%
(5)
ADP200 • Quick installation guide - Specifications and connection
SEQ
SEQ . 04
PAR: 2116
E
Resolver pole pairs
1
Def:
1
SEQ
SEQ . 04
PAR: 2118
E
Resolver frequency
5000
Hz
Def:
5000
SEQ
SEQ . 01
Autophase rotation
Press E to exe c ute
(3)
Auto phase
Done
SEQ
SEQ . 01
Autophase still
Press E to exe c ute
(3)
Auto phase
Done
SEQ
SEQ . 04
PAR: 2116
Resolver pole pairs
000000001
Def:
1
SEQ
SEQ . 04
PAR: 2118
Resolver frequency
000005000
Hz
Def:
5000
Auto phase
PAR: 2190
E
Progress 0%
(4)
03 STARTUP WIZARD
Open Enable input
Auto phase
PAR: 2192
E
Progress 0%
(4)
03 STARTUP WIZARD
Open Enable input
2
E
5001 Hz
E
4999 Hz

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents