6. Collect an XSCF snapshot to archive the system status for future reference.
XSCF>
7. Upload the XCP 1060 upgrade image by using the command line
getflashimage.
XSCF> getflashimage http://server.domain.com/XCP1060/images/FFXCP1060.tar.gz
The BUI on the XSCFU can also be used to upload the XCP 1060 upgrade image.
8. Update the firmware by using the flashupdate (8) command.
Caution – Flashupdate will update one bank, reset the XSCF, and commence
update of the second bank. Verify that the current and reserve banks are both
updated. If both banks indicate XCP revision 1060, proceed to the next step.
XSCF>
Specify the XCP version to be updated. In this example, it is 1060.
9. Confirm completion of the update.
XSCF> showlogs event
Confirm no abnormality happens while updating the XSCF.
10. Confirm that both the current and reserve banks of the XSCFU display the
updated XCP versions.
XSCF>
XSCF#0 (Active )
XCP0 (Reserve): 1060
XCP1 (Current): 1060
XSCF>
If the Current and Reserve banks on the XSCF do not indicate XCP revision 1060,
contact your authorized service representative.
26
Sun SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • November 2007
snapshot -t user@host:directory
flashupdate -c update -m xcp -s 1060
version -c xcp

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARC Enterprise M5000 and is the answer not in the manual?

This manual is also suitable for:

Sparc enterprise m4000

Table of Contents