Software Documentation Updates (Continued)
TABLE 9
Document
Sun SPARC Enterprise
M4000/M5000/M8000/M9000
Servers XSCF Reference
Manual
Sun SPARC Enterprise
M4000/M5000/M8000/M9000
Servers XSCF Reference
Manual
32
Sun SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • November 2007
Page Number
Change
The following description is added in EXTENDED
setpowerupde
DESCRIPTION:
lay(8)
manpage
When the power is turned on from the operator panel, the
wait time and warm-up time that you set are ignored. If you
have set these times and wish for the system to use them at
startup, perform the poweron(8) command.
The -p user option requires useradm privileges.
setupplatfor
m(8) manpage
The -p network option requires either platadm or
fieldeng privileges.
The -p altitude option requires platadm privileges.
The -p timezone option requires platadm privileges.