11. Confirm the newly introduced 'servicetag' facility is enabled.
When a system is upgraded from XCP 104x to XCP 1050 or later, the newly
introduced 'servicetag' facility is not automatically enabled.
a. Check the 'servicetag' facility status by using the showservicetag CLI.
XSCF> showservicetag
Disabled
b. If it is currently disabled, you must enable it.
XSCF> setservicetag -c enable
Settings will take effect the next time the XSCF is rebooted.
c. An XSCF reboot is required for the 'servicetag' facility to be enabled.
XSCF> rebootxscf
The XSCF will be reset. Continue? [y|n] :y
Note – Service tags are used by Sun Service. Fujitsu customers cannot enable service
tags.
d. Wait until XSCF firmware reaches the ready state.
This can be confirmed when the READY LED of the XSCF remains lit, or the
message 'XSCF Initialize complete' appears on the serial console.
12. Turn off all of the server's power switches for 30 seconds.
13. After 30 seconds, turn the power switches back on.
14. Wait until the XSCF firmware reaches the ready state.
This can be confirmed when the READY LED of the XSCF remains lit.
15. Log in on to the XSCFU using a serial connection or LAN connection.
16. Confirm no abnormality occurred by using showlogs error -v and showstatus
commands.
showlogs error -v
XSCF>
XSCF>
showstatus
If you encounter any hardware abnormality of the XSCF contact your authorized
service representative.
Sun SPARC Enterprise M4000/M5000 Servers Product Notes
27