Cool Wall Mantel Clearances; Cool Wall Mantel Leg Clearances - Regency Grandview G800C Owners & Installation Manual

Medium dv gas fireplace
Table of Contents

Advertisement

Cool Wall Mantel Clearances

Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram below.
14
14"
10
5
B
0
Inches
Mantel Clearances
G800C
From Top of Fireplace
32-1/2"
Opening
(826mm)
Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.
Note: If Faceplate or Finishing Trim is being installed, leave 3 3/8" clearance from from top of fireplace opening for installation
and removal.

Cool Wall Mantel Leg Clearances

32-1/2" (826mm) overall fireplace width
See framing dimensions on next page.
Mantel Clearances
12
10
8
6
4
2
7"
C
2"
Top of
A
Fireplace
Opening
To Floor
A
B
10"
(254mm)
(127mm)
TopView
Side opening
of fireplace
Combustible
C
5"
2" (51mm)
3" (76mm)
1-3/4"
(44mm)
Allowable mantel leg
projection
installation
Grandview® G800C Gas Fireplace
|
19

Hide quick links:

Advertisement

Table of Contents
loading