Installer's Information; Installation Checklist; Locating Your Gas Fireplace - Regency Grandview G800C Owners & Installation Manual

Medium dv gas fireplace
Table of Contents

Advertisement

installer's information

Installation Checklist

1. Locate appliance
a)
Room location (Refer to "Locating Your
Gas fireplace" section)
b)
Clearances to Combustibles (Refer to
"Clearances" section)
c)
Mantle Clearances (Refer to "Com-
bustible Mantel Clearances" section)
d)
Framing & Finishing Requirements
(Refer to "Framing & Finishing" section)
e)
Venting Requirements (Refer to "Vent-
ing" section)
2. Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to
"Unit Assembly Prior to Installation" Section).
NOTE: Must be done before installing unit
into place.
3. Install vent (Refer to "Venting" sections).
4. Make gas connections. Test the pilot. Must be
as per Diagram (Refer to "Pilot Adjustment "
section).
Convert to propane if desired (Refer to "Gas
Line Installation" and "Conversion Kit from
NG to LPG" sections).
5. Make electrical connections to receptacle
supplied with unit (recommended).
6. Install standard and optional features. Refer
to the following sections:
a. Standard Glass Door
b. Rear to top vent conversion
c. Coolwall conversion
d. Fan Installation (Optional)
e. Nailing flange installation
f. Electrical access/120 volt power installation
by others
g. Wall Mount On/OFf Switch + Receiver
Installation
h. Coolwall Clearances/Framing/Finishing
i. Clean Front Clearance/ Framing/Finishing
j. Outside Finish Clearance/ Framing/
Finishing
k. LP Conversion (optional)
l. Inner Panels or Brick Panels (Must install
one of the options)
m. Media (Glass crystals)
n. Log Set Installation
IMPORTANT: If installing the fan kit or changing
this from rear vent to top vent, this must be
completed prior to installing the appliance
into the framed opening.
7. Final check.
|
14
Grandview® G800C Gas Fireplace
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label 27,000 Btu/h
for natural gas and propane), after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

Locating Your Gas Fireplace

1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat,
solid, continuous surface For example a
wood, metal or concrete floor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
3. The G800C Gas Fireplace can be installed
in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
4. This appliance is Listed for bedroom installations
using the standard Remote (millivolt thermostat
system). Some areas may have further require-
ments, check local codes before installation.
5. The G800C Gas Fireplace are approved for alcove
installations, see "Clearances" section for details.
6. We recommend that you plan your installation on
paper using exact measurements for clearances
and floor protection before actually installing this
appliance. Have an authorized inspector, dealer,
or installer review your plans before installation.
Diagram 1