On/Off Key - Mitel Aastra 470 System Manual

R3.2
Hide thumbs Also See for Aastra 470:
Table of Contents

Advertisement

6. 4. 2

On/Off key

Pressing the On/Off button starts up the call manager (which is switched off ).
In normal operation a short key press of the On/Off key brings up the Shut Down
menu, offering the choice of shutting down the Call Manager, the application
server or the entire communication server. The navigation keys are used to select
from the menu.
Tab. 88
On/Off key
Function
Start the call manager
Shut down the communica-
tion server, call manager or
applications server
Force Call Manager shut
down
1)
Shutting down the applications server can take some time and can be checked using the status LED on the
On/Off button (see
Tab.
2)
This corresponds to the "Off state" in accordance with EU Directive 2005/32/EC.
Notes:
Never disconnect the communication server from the power supply to
trigger a restart. This can result in data losses and prevent a restart.
Tips
– The shutdown menu can also be used via the Call Managers control
panel. A restart menu is also available, in which CPU1 and CPU2 can be
restarted separately.
– CPU1 and CPU2 can also be restarted via WebAdmin.
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014
Action
Note
Short key press Requirements:
• Power supply on
• Executable system software loaded
Short key press The display shows the Shut Down menu with the following
selection:
• Shut down full system: Shut down communication server
(CPU1 and CPU2
• Shut down Call Manager: Shut down CPU1 only
• Shut down Application Server: Shut down CPU2
Keypress longer
Note:
than 6 seconds
The forced shut-down of the Call Manager should only be
made if shutting down via the Shut Down menu is no longer
possible for whatever reason.
95).
Operation and Maintenance
1)
2)
).
1)
only
225

Advertisement

Table of Contents
loading

Table of Contents